Peng Long, Su Sen, Han Kun, et al. Study on Dynamic Characteristics of Dual‑Rotor Magnetically Levitated Flywheel Energy Storage System[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-11.
Peng Long, Su Sen, Han Kun, et al. Study on Dynamic Characteristics of Dual‑Rotor Magnetically Levitated Flywheel Energy Storage System[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-11.DOI: 10.19799/j.cnki.2095-4239.2026.0732.
Study on Dynamic Characteristics of Dual‑Rotor Magnetically Levitated Flywheel Energy Storage System
Aiming at the technical challenge of limited motor heat dissipation under vacuum conditions in high-power flywheel energy storage systems
this paper proposes a novel structure with separated motor and flywheel rotors. In this configuration
the flywheel rotor is placed inside the vacuum chamber while the motor rotor is arranged in an atmospheric environment outside the chamber
and contactless torque transmission is realized via a tubular magnetic coupling. Based on the Newton-Euler equations
a dual-rotor dynamic model is established
which comprehensively considers the gyroscopic moment
stiffness and damping of magnetic bearings
as well as the radial coupling stiffness of the magnetic coupling. Electromagnetic field simulations show that the ultimate torque of the magnetic coupling is 11.26 kN·m
and its equivalent radial stiffness ranges from -416.40 to -445.58 N/mm within the operating torque range of 0~10 kN·m. Dynamic analyses reveal that the critical speeds of the first seven rigid-body modes of the system are 371.21~1988.10 r/min
and the first bending critical speed is 13707 r/min
indicating sufficient safety margin within the operating speed range. Unbalance excitation induces synchronous resonance on both the flywheel and motor sides
with maximum vibration displacements of 65.19 μm and 30.23 μm
respectively. Parameter sensitivity results demonstrate that the magnetic bearing stiffness dominates the low-order critical speeds of the system
damping can reduce the resonance amplitude by more than 70%
whereas the coupling stiffness has a minor effect on the system dynamic performance. A 1.2 MW-125 kWh prototype is constructed and full-speed vibration tests are carried out. The experimental results agree well with the simulation trends
providing a theoretical reference for the design of such dual-rotor flywheel energy storage systems.
Mai Q ,Hu Q ,Chen X .A Comprehensive Analysis of the Loss Mechanism and Thermal Behavior of a High-Speed Magnetic Field-Modulated Motor for a Flywheel Energy Storage System[J].Machines,2025,13(6):465-465.
Liu M ,Wang N ,Chen X , et al.Periodic Motion Characteristics of a Magnetic Suspended Dual-Rotor System with Nonlinear Bearing Effects[J].Sensors,2026,26(14):4400-4400.