LIU Xiaogang, XU Dongye, HAN Yun, et al. Temperature evolution of compressed air energy storage caverns under different initial charging modes[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-12.
LIU Xiaogang, XU Dongye, HAN Yun, et al. Temperature evolution of compressed air energy storage caverns under different initial charging modes[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-12.DOI: 10.19799/j.cnki.2095-4239.2026.0706.
Temperature evolution of compressed air energy storage caverns under different initial charging modes
To accurately characterize the temperature evolution in compressed air energy storage (CAES) caverns under different charging modes and achieve effective control of cavern temperature rise
a coupled thermo-fluid numerical model accounting for the gravitational effect on air was developed based on the Peng-Robinson real-gas equation of state. The model was used to systematically elucidate the mechanism by which gravity affects the temperature field in a CAES cavern. The temperature-rise characteristics under different charging modes were then investigated
and corresponding thermal regulation strategies were proposed. The results show that the gravitational effect on air cannot be neglected when numerically simulating the thermal response of a vertical-tank CAES cavern. Air density differences induced by temperature gradients
together with gravity
substantially enhance air circulation within the cavern
increasing the air velocity near the vertical walls to 7-8 m/s
approximately 14-16 times the value obtained when gravity is neglected (0.5 m/s). Consequently
the peak volume-averaged air temperature decreases from 128.3℃ to 80.4℃
representing a reduction of 37.3%. The spatial distribution of air temperature also becomes more uniform
and the difference between the temperature in local high-temperature regions and the volume-averaged air temperature is significantly reduced. Extending the initial charging duration and adopting a staged charging mode with a lower charging rate at the low-pressure stage both effectively reduce the peak air temperature and the temperature-rise rate. When the initial charging duration increases from 24 h to 72 h
the peak volume-averaged air temperature decreases by approximately 21%. When the charging duration in the low-pressure range of 0.1-0.3 MPa is extended from 1.0 h to 2.6 h
the peak air temperature decreases by approximately 14.0℃. Accordingly
a temperature-rise regulation strategy combining an extended initial charging duration with a reduced charging rate at the low-pressure stage is proposed for CAES caverns.
关键词
Keywords
references
BUDT M, WOLF D, SPAN R, et al. A review on compressed air energy storage: Basic principles, past milestones and recent developments[J]. Applied Energy, 2016, 170: 250-268.
BAZDAR E, SAMETI M, NASIRI F, et al. Compressed air energy storage in integrated energy systems: A review[J]. Renewable and Sustainable Energy Reviews, 2022, 167: 112701.
YANG C H, WANG T T. Opportunities, Challenges and Development Suggestions for Deep Earth Energy Storage in China [J]. Chinese Science Bulletin, 2023, 68(36): 4887-4894.
YANG C, WANG T T, CHEN H. Theoretical and technological challenges of deep underground energy storage in China[J]. Engineering, 2023, 25: 168-181.
SUN G H, ZHU K Y, JI W D, et al. Basic Concepts, Design Principles, and Methods for Underground Caverns in Compressed Air Energy Storage Power Plants [J]. Disaster Prevention and Control in Tunnels and Underground Engineering, 2024, 6(01): 14–23.
SUN G, WANG J, YU X Y, et al. Research Progress on the Basic Principles and Analysis Methods of Underground Lined Caverns for Compressed Air Energy Storage Power Plants [J]. Rock and Soil Mechanics, 2025, 46(01): 1–25.
XIA K Z, XIANG X, MIAO X X, et al. Key Issues and Technologies for Large-Scale Compressed Air Energy Storage in Underground Cavities Lined with Hard Rock [J]. Journal of Huazhong University of Science and Technology (Natural Science Edition), 2025, 53(08): 106–125.
CROTOGINO F, MOHMEYER K U, SCHARF R. Huntorf CAES: More than 20 years of successful operation[C]//SMRI Spring Meeting. Orlando, USA, 2001.
KIM H M, RUTQVIST J, RYU D W, et al. Exploring the concept of compressed air energy storage (CAES) in lined rock caverns at shallow depth: A modeling study of air tightness and energy balance[J]. Applied Energy, 2012, 92: 653-667.
KUSHNIR R, DAYAN A, ULLMANN A. Temperature and pressure variations within compressed air energy storage caverns[J]. International Journal of Heat and Mass Transfer, 2012, 55(21/22): 5616-5630.
RAJU M, KHAITAN S K. Modeling and simulation of compressed air storage in caverns: A case study of the Huntorf plant[J]. Applied Energy, 2012, 89(1): 474-481.
XIA C C, ZHOU Y, ZHOU S W, et al. A simplified and unified analytical solution for temperature and pressure variations in compressed air energy storage caverns[J]. Renewable Energy, 2015, 74: 718-726.
LIU L Y, JIANG Z M, WANG J Y, et al. Analysis of Thermodynamic Processes in Underground Compressed Air Storage Facilities for Compressed Air Energy Storage Power Plants [J]. Energy Storage Science and Technology, 2018, 7(02): 232–239.
JIANG Z M, GUO J, TANG D. Compressed air energy storage underground gas storage compressed wet air thermodynamic model [J]. Energy storage science and techn-ology, 2021, 10 (02): 638-646.
JIANG Z M, LIAO J H, XIAO Z Z, et al. Underground gas storage of compressed air energy storage therm-odynamics improved model study [J]. Journal of changsha university of science and technology (natural science edition), 2024, 21 (02): 32-41.
ZHOU S W, XIA C C, ZHANG P Y, et al. Stress calculation caused by pressure and temperature in undergrou-nd compressed gas energy storage circular liner chambers [J]. Chinese Journal of Geotechnical Engineering, 2014, 36(11): 2025-2035.
VERSTEEG H K, MALALASEKERA W. An introduction to computational fluid dynamics: the finite volume method[M]. 2nd ed. Harlow: Pearson Education, 2007.
GENG X, SUN G H, WU K, et al. Thermodynamic analysis of lined rock caverns for initial inflation and cyclic operational conditions in compressed air energy storage[J]. Journal of Energy Storage, 2024, 99: 113253.
JIANG Z M, OU YANG Y R, HAN K W, et al. Spatio-temporal distribution and Temperature control method of Compressed Air in Underground gas storage [J]. Chinese Journal of Engineering Thermophysics, 2023, 44(12): 3433-3444.
SUN G H, GENG X, YU X Y, et al. Temperature Response and Local high-temperature Control Method for the First Inflation of Underground Cavern in Compressed Air Energy Storage Power Station [J]. Thermal Power Generation, 2024, 53(09): 29-38.
LIAO J H, JIANG Z M, OU YANG Y R, et al. Numerical investigation on thermodynamic features and exergy efficiency of man-made caverns for CAES[J]. Thermal Science and Engineering Progress, 2025, 68: 104305.
陈国栋. 地下盐穴储气库注采运行热力工况及稳定性分析[D]. 中国石油大学(北京), 2023.
CHEN G D. Analysis of Thermal Conditions and Stability During Injection and Production Operations in Underground Salt Cavity Gas Storage Facilities [D]. China University of Petroleum (Beijing), 2023.
Peng D Y, Robinson D B. A new two-constant equation of state[J]. Industrial & Engineering Chemistry Fundamentals, 1976, 15(1): 59–64.
Bell I H, Satyro M, Lemmon E W. Consistent Twu parameters for more than 2500 pure fluids from critically evaluated experimental data[J]. Journal of Chemical & Engineering Data, 2018, 63(7): 2402–2409.
Investigation on the thermo-mechanical coupling characteristics of salt caverns for compressed air energy storage
Load characteristics and design recommendations for lined rock caverns in shallow-buried compressed air energy storage considering thermal strain mismatch and interlayer slip
Research status on development and application of monitoring technology for salt cavern gas storage in compressed air energy storage intelligent field stations
Dynamic analysis of large-scale compressed air energy storage systems considering volume effect and thermal capacity effect
Suitability assessment and zoning for the construction of compressed air energy storage plants in China
Related Author
WANG Fan
CHEN Shiqing
ZHOU Xuezhi
XU Yujie
CHEN Haisheng
WANG Zijun
YAN Zhiyuan
WEN Rui
Related Institution
Research Center of Fluid Machinery Engineering and Technology, Jiangsu University
Institute of Engineering Thermophysics, Chinese Academy of Sciences
Key Laboratory of Long-Duration and Large-Scale Energy Storage (Chinese Academy of Sciences)
College of Water Conservancy and Hydropower Engineering, Hohai University
Shanghai Investigation, Design & Research Institute Co., Ltd.