Bi-Level Optimization Strategy for Frequency-Regulation Power Allocation Among Multiple Energy Storage Power Stations Based on Stochastic MPC and a Multi-Objective Genetic Algorithm
|更新时间:2026-10-16
|
Bi-Level Optimization Strategy for Frequency-Regulation Power Allocation Among Multiple Energy Storage Power Stations Based on Stochastic MPC and a Multi-Objective Genetic Algorithm
Energy Storage Science and TechnologyPages: 1-13(2026)
LI Junhui, GU Changxu, QI Jun, et al. Bi-Level Optimization Strategy for Frequency-Regulation Power Allocation Among Multiple Energy Storage Power Stations Based on Stochastic MPC and a Multi-Objective Genetic Algorithm[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-13.
LI Junhui, GU Changxu, QI Jun, et al. Bi-Level Optimization Strategy for Frequency-Regulation Power Allocation Among Multiple Energy Storage Power Stations Based on Stochastic MPC and a Multi-Objective Genetic Algorithm[J]. Energy Storage Science and Technology, XXXX, XX(XX): 1-13.DOI: 10.19799/j.cnki.2095-4239.2026.0659.
Bi-Level Optimization Strategy for Frequency-Regulation Power Allocation Among Multiple Energy Storage Power Stations Based on Stochastic MPC and a Multi-Objective Genetic Algorithm
A bi-level allocation method integrating stochastic model predictive control (SMPC)with a multi-objective genetic algorithm (MOGA) is developed for power allocation among wind farms
thermal power units
and multiple energy storage power stations participating in coordinated frequency regulation in power grids with a high penetration of renewable energy. The upper layer considers the frequency-regulation costs of different regulation resources and dynamic wind-turbine deloading. It combines automatic generation control (AGC) command forecasts with forecast-error information and applies a boundary-tightening method to handle chance constraints on the state of charge (SOC) of energy storage
thereby addressing the effects of forecast errors on storage SOC and frequency-regulation power allocation. Meanwhile
the participation level of wind turbines in frequency regulation is dynamically adjusted according to the SOC of the energy storage system
and the frequency-regulation power among wind power
thermal power
and energy storage is allocated. In the lower layer
adaptive weights are constructed according to the extent to which the predicted SOC of each energy storage power station approaches its operating boundaries over the prediction horizon. The adaptive weights are incorporated into the SOC-balancing objective function to strengthen the regulation of power stations exposed to higher boundary risks. With frequency-regulation cost minimization and weighted SOC balancing as the optimization objectives
MOGA is used to obtain a Pareto solution set. The optimal solution is then selected from the solution set by calculating a comprehensive evaluation value based on the adaptive weights
thereby realizing optimized frequency-regulation power allocation among the energy storage power stations. Simulation results show that the proposed strategy significantly reduces the overall SOC boundary-violation risk of energy storage and wind-turbine deloading while maintaining the economic performance of frequency regulation
and effectively improves SOC balance among the energy storage power stations
thereby enhancing the sustained frequency regulation capability of the system.
LI G Q, LIU X C, XIN Y C, et al. Research on frequency stability of power system with high penetration renewable energy: A review[J]. High Voltage Engineering, 2024, 50(3): 1165-1181.
Pan Y L, Dong F. Dynamic evolution and driving factors of new energy development: Fresh evidence from China[J ] . Technological Forecasting & Social Change, 2022, 176 .
YUAN W. Analysis on the development status of new energy industry under the background of low-carbon economy[J]. Energy Storage Science and Technology, 2023, 12(11): 3589-3590.
ZHANG L H, LIU X Y, GU X P, et al. Review and prospects of frequency security and stability research in new-type power systems[J]. Zhejiang Electric Power, 2024, 43(10): 12-26.
HAN Z L, JU P, QIN C, et al. Review and prospect of research on frequency security of new power system[J]. Electric Power Automation Equipment, 2023, 43(9): 112-124.
ZHOU T, HE W, LI H F, et al. A review of energy storage-assisted operation and optimal configuration in new-type power systems[J]. Journal of Nanjing University of Information Science & Technology (Natural Science Edition), 2025, 17(5): 715-730.
WANG S L, CHENG L W, ZHOU L, et al. Evolution and research dynamics of emerging energy storage technologies[J]. Journal of Wuhan University (Natural Science Edition), 2025, 71(6): 763-781.
LI C P, SI W B, LI J H, et al. Two-layer optimization of frequency modulated power of thermal generation and multi-storage system based on ensemble empirical mode decomposition and multi-objective genetic algorithm[J]. Transactions of China Electrotechnical Society, 2024, 39(7): 2017-2032.
YU H Q, LIN T, QI M X. Combined frequency modulation strategy for thermal power and energy storage based on SSA-VMD and double-layer fuzzy control[J]. Journal of Power Supply, 2025, 23(4): 274-285.
Wang X L, Li X D, Ni W D, et al. A Model Predictive Control Based Optimal Task Allocation among Multiple Energy Storage Systems for Secondary Frequency Regulation Service Provision[J]. Energies, 2023, 16(3): 1228-1228.
ZHU Y, SHI Q, CAI S G, et al. Wind-storage joint frequency modulation and power optimization allocation based on two-dimensional dynamic load reduction and two-layer MPC[J]. Electric Power Automation Equipment, 2024, 44(8): 1-8.
LIU C B, JIAO W S, WU Q W, et al. Strategy of wind-storage combined system participating in power system secondary frequency regulation based on model predictive control[J]. Journal of Shanghai Jiao Tong University, 2024, 58(1): 91-101.
WEI W R, MIAO S H, WANG T T, et al. Optimal distribution method for frequency regulation commands considering the state of charge recovery and adjustment[J]. Proceedings of the CSEE, 2024, 44(S1): 53-65.
LI J H, HOU T, YAN G G, et al. Two-layer optimization of frequency modulation power in multi-battery energy storage system considering frequency modulation cost and recovery of state of charge[J]. Proceedings of the CSEE, 2021, 41(23): 8020-8033.
LI J H, SONG Q L, GUO Q, et al. Bi-level optimization strategy of grid-side multiple energy storage stations considering available capacity and frequency regulation cost[J]. Automation of Electric Power Systems, 2025, 49(10): 101-111.
DANG S J, SUN L Q, WANG S Y, et al. A dual-layer power optimization strategy for multi-energy storage power station considering system economic efficiency and state of charge balance[J]. Energy Storage Science and Technology, 2025, 14(3): 1247-1257.
LEE S J, KIM J H, KIM C H, et al. Coordinated Control Algorithm for Distributed Battery Energy Storage Systems for Mitigating Voltage and Frequency Deviations[J]. IEEE transactions on smart grid, 2016, 7(3): 1713-1722.
SUN L Q, DANG S J, LIU G, et al. A frequency-modulation power optimization method for energy storage power stations considering the transition state of charge-discharge and power constraints[J]. Energy Storage Science and Technology, 2025, 14(3): 1286-1298.
ZHENG Z X, CHEN E Z, LI J, et al. Optimization strategy for secondary frequency regulation power of energy storage cluster based on synthesis consumption[J]. Proceedings of the CSEE, 2026, 46(7): 2796-2808.